Product Description
The Mercury online UPS series offers high frequency, double-conversion technology uninterruptible power supply systems that provide maximum power protection for mission-critical equipment. Such equipment require always-on power supply, with zero switching time, which only online power backup systems can provide. Moreover, they also need the purest quality of power, of pure sine wave. The Mercury online UPS provide that ideal power backup supply for critical, sensitive equipment, ensuring, too, that they are protected from power problems in the AC line.
The 10kva Mercury online UPS has a rating of 7000W, providing ample capacity to meet a significant load. Whether it's networking equipment, servers, workstations or other IT equipment and mission-critical applications, you can trust the Mercury 10kva online UPS to deliver the performance for your smooth business operations. Best of all, this range of online UPS comes at prices that are relatively budget-friendly.
Features
- Application: network, servers and other IT equipment
- High frequency and double conversion on-line technology
- Fully digitized microprocessor control
- Wide input voltage range
- UPS startup without battery
- Cold start
- Advanced battery management
- Advanced battery charge in UPS off mode
- Lightning and surge protection
- Short circuit and surge protection
- Fan speed auto control when loads varies
- Optional extension battery pack
- Load capacity display
- Smart RS232 communication with monitoring software
- Optional SNMP Card slot
Power | |
Power | 10KVA / 7000W |
Voltage range | 176 ±5VAC~276 ±5VAC, |
Frequency | 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto sensing |
Input phase | Single phase |
Power factor | ?0.98 |
Voltage range | 220VAC ±1% |
Output phase | Single phase |
Frequency | 50Hz ±0.2% (battery mode) |
THD | < 2% (Linear load); < 6% (non-Linear load) |
Overload | 105%~130% 10min turn to Bypass mode, > 130% 1s turn to Bypass mode |
Crest factor | 3:1 (max) |
Waveform | Pure sine wave |
Transfer time | 0ms (AC mode - Battery mode) 0ms (AC mode - Bypass mode) |
Efficiency | ?88% |
AC mode | 5 cycles turn off inverter, no transfer to Bypass, provide alarm. |
Battery mode | 5 cycles turn off inverter, provide alarm. |
Bypass mode | Input fuse blown or break action. |
Battery Model | 12V sealed lead acid maintenance free |
DC voltage | 240VDC |
Configuration | 20x 12V/8.2AH |
Backup time | 13min (half load) / 5min (full load) |
Charge current | 1A (standard unit) / 5A (long time unit) |
Recharge time | 90% capacity after 8hrs charging |
Communication Interface | RS232; SNMP (optional) |
Parallel Port | Parallel availability for redundancy and load sharing up to three unit |
LCD Indication | Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as on batt or on bypass |
LED Indication | Green: normal operation; Yellow: warning condition Red: abnormal operation |
Noise level | ? 55dB |
Temperature | 0~40?C; 0 ~ 40?C (storage temperature) |
Humidity | 0~95% (non-condensing) |
Altitude | < 1500m |
Weight Net/Gross | 92/107kg (standard unit); 36/51kg (long time unit) |
Dimension (WxDxH) | 270 x 570 x 720mm |