APC BX1600MI-MS  Back-UPS 1600VA, 230V, AVR, 4 universal outlets BX1600MI-MS
APC BX1600MI-MS Back-UPS 1600VA, 230V, AVR, 4 universal outlets BX1600MI-MS
NGN310,468.95
Availability:
In stock
Out of stock
SKU
deluxe----1647014210
Brand
Weight
6 kg

Product Description

Main

Run time for load

W

information_stroke

Min-max: 90-900 W

2min 33s

Max. Capacity Used

information_stroke

100 %

Main Input Voltage 230 V
Main Output Voltage 230 V
rated power in W 900 W
rated power in VA 1600 VA
plug standard IEC 60320 C14
nb of power socket outlets 4 universal
cable length 1.22 m
number of cables 1
battery type Lead-acid battery
General
provided equipment User manual
max runtime 240 min
Number of power module free slots 0
Number of power module filled slots 0
redundant No
Physical
colour Black
height 19 cm
width 14 cm
depth 39 cm
net weight 10.3 kg
mounting preference No preference
mounting mode Not rack-mountable
two post mountable 0
USB compatible No
Input
network frequency 50/60 Hz +/- 5 Hz auto-sensing
input voltage limits 140...300 V
Input Power Factor at Full Load 0.56
Output
Maximum configurable power in W 900 W
output frequency 50/60 Hz +/- 1 Hz sync to mains
UPS type Line interactive
Wave type Stepped approximation to a sinewave
full load runtime 00:01:00 900 W
half load runtime 00:06:30 450 W
Maximum configurable power in VA 1600 VA
Transfer time 6 ms typical : 10 ms maximum
Conformance
product certifications CE
standards EN/IEC 62040-1
EN/IEC 62040-2
CE
equipment protection policy Lifetime : 50000 euros
Environmental
ambient air temperature for operation 0…40 °C
relative humidity 0…95 % non-condensing
operating altitude 0...3000 m
ambient air temperature for storage -15…40 °C
storage Relative Humidity 0…95 % Non-condensing
storage altitude 0…3000 m
acoustic level 40 dBA
IP degree of protection IP20
Batteries & Runtime
Run Time View Runtime Graph

action_new_window

Efficiency View Efficiency Graph

action_new_window

number of battery filled slots 0
number of battery free slots 0
Battery recharge time 8 h
battery voltage 24 V
Battery power in VAH 136 VAh runtime
168 VAh capacity
battery life 3…5 year(s)
Battery graph comments Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output.
extended runtime 0
Communications & Management
control panel LED Status display with on line : on battery
alarm Alarm when on battery : distinctive low battery alarm
Surge Protection and Filtering
Surge energy rate 273 J
Data line protection RJ45 10/100/1000 Base-T Ethernet protection
Packing Units
Package 1 Weight 11.3 kg
Package 1 Height 29.7 cm
Package 1 width 23.5 cm
Package 1 Length 49.5 cm
SCC14 10731304410727